Новое имя сервера Sun X3-2
Сервер Sun X3-2 ранее назывался сервером Sun Fire X4170 M3.
Это прежнее название может по-прежнему отображаться в программном обеспечении.
Изменение имени не означает каких-либо изменений в системных функциях.
Комплектация:
номер модель описание количество
1 7102703 Sun Server X3-2: model family 1
2 SG-SAS6-R-INT-Z Sun Storage 6 Gb SAS PCIe RAID HBA, Internal: 8 port and 512 MB cache (for factory installation) 1
3 7100599 1 Intel(R) Xeon(R) E5-2690 8-core 2.9 GHz processor (for factory installation) 2
4 7101758 Heatsink (for factory installation) 2
5 7100730 One 8 GB DDR3-1600 DIMM (for factory installation) 2
6 RA-SS2CF-600G10K2 One 600 GB 10000 rpm 2.5-inch SAS-2 HDD with bracket (for factory installation) 4
7 7102735 Sun Server X3-2: 1 RU base chassis with motherboard, 2 PSUs, slide rail kit, and cable management arm 1
8 7102748 PCIe filler panel (for factory installation) 3
9 7102740 Four 2.5-inch drive slots and 1 DVD-RW disk cage 1
10 333V-20-15-C14 Power cord: Sun Rack jumper, straight, 2 meters, C14 plug, C13 connector, 15 A (for factory installation) 2
Processor | |
Number | Two Quad-Core, 6-Core, or 8-Core |
Architecture | Type: Intel Xeon E5-2600 family |
CPUs | Intel 2.4GHz Quad-Core Xeon E5-2609 (10MB, 80W) Intel 2.5GHz 6-Core Xeon E5-2640 (15MB, 95W) Intel 2.2 GHz 8-Core Xeon E5-2660 (20MB, 95W) Intel 2.9GHz 8-Core Xeon E5-2690 (20MB, 135W) |
Cache | L1: 32KB Instruction and 32KB data L1 cache per core L2: 256KB shred data and instruction L2 cache per core L3: Up to 20MB shared inclusive L3 cache per processor |
Main Memory | |
Capacities | Total DIMM slots: 16 DIMM type: DDR3 1066MHz or 1600MHz Registered DIMMs DIMM size: 8GB 1600MHz, 16GB 1600MHz, or 32GB 1066MHz Maximum capacity: 512GB (when configured with 32GB DIMMs) |
Standard Integrated Interfaces | |
Network | Supports Four 100/1000/10000 Base-T Ethernet Ports (100 at full-duplex only) |
Network Management | One dedicated 10/100Base-T Ethernet port |
Serial Management | One dedicated RJ45 port |
USB | Front: Two USB 2.0 ports Rear: Two USB 2.0 ports Internal: Two USB 2.0 ports |
PCI Expansion Slots |
Four low profile PCI Express 3.0 slots; |
Internal Mass Storage | |
Disks | 4-Disk configuration with DVD: 2.5in 300GB / 600GB SAS-2 or 100GB / 300GB SSD 4-Disk configuration: 3.5in 600GB SAS-2 or 3TB SAS 8-Disk configuration: 2.5in 300GB / 600GB SAS-2 or 100GB / 300GB SSD |
Uses one of two supported internal HBAs for internal storage. The HBA is to be installed in PCI Express Slot 4 (internal access only, under PSI Express Slot 3) | |
Power Supplies | |
Dual redundant, hot swappable power supplies (Power supply rating output = 600W) |
|
Environment | |
Voltage | 100 to 127 / 200 to 240 VAC (90 to 132/180 to 264 VAC ranges) |
Input Current | 7.2 A @ 100 VAC (720 VA) Max |
AC power | 50-60 Hz (47 to 63 Hz range) |
Temperature | Operating: 5° C to 35° C (41° F to 95° F) Nonoperating: -40° C to 70° C (-40° F to 158° F) Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3,000 meters of elevation.) |
Humidity | Operating: 10% to 90% relative humidity noncondensing, short term -5 ° C to 55° C (25° F to 113° F) ; 5% to 90% noncondensing, but not to exceed 0.024 kg of water per kg of dry air (0.053 lbs water / 2.205 lbs dry air) Nonoperating: up to 93% relative humidity noncondensing, 37.7° C (100.4° F) max wet bulb |
Altitude | Operating: up to 3000 m (9,840 ft.) at 35° C (95° F) Nonoperating: Maximum 12,000 m (39,370 ft) |
Acoustic | 7.91 Bels A weighted operating; 5.28 Bels A weighted idling |
Regulations Meets or exceeds the following requirements: |
|
Safety | UL/CSA-60950-1, 2nd Edition, 2007-03-27 ; EN60950-1:2006 +A11:2009 +A1:2010 +A12:2011 ; IEC60950-1:2005 +A1:2009CB Scheme with all country deviations ; CNS14336-1 ; GB4943 |
EMI | EN55022:2006 +A1:2007/CISPR22:2008 Class A ; 47 CFR 15B Class A ; ICES-003 Class A ; VCCI Class A ; AS/NZ 3548 Class A ; CNS 13438 Class A ; KSC 5858 Class A ; GB9254 Class A ; EN61000-3-2 ; GB17625.1 ; EN61000-3-3 |
Immunity | EN55024:2010 ; IEC 61000-4-2 Electrostatic discharge ; IEC 61000-4-3 RF E-field immunity ; IEC 61000-4-4 Electrical Fast Transient/Burst ; IEC 61000-4-5 Surge ; IEC 61000-4-6 RF-Conducted immunity ; IEC 61000-4-8 Power frequency magnetic field immunity ; IEC 61000-4-11 Voltage dips, short interruptions |
Ergonomics | EK1-1TB-2000 |
Dimensions and Weight | |
Height | 42.6 mm (1.7 in) |
Width | With Bezel: 482.4 mm (18.9 in) Server Chassis: 436.5 mm (17.185 in) |
Depth | 737 mm (29 in) Max |
Weight | 24.3 kg (53.4 lbs) |
Clearance and Service Access | |
Front Rear |
91 cm (36 in) 91 cm (36 in) |
Rack Mounting | |
Sun Server X3-2 / Sun Fire X4170 M3 Server Racks | Racks are as follows:
|